Mileva 332019-05-21T11:40:28+00:00

OGI for hydrocarbons gas leaks

Request info

MILEVA 33 is the latest model of Optical Gas Imaging for micro-leaks detection of hydrocarbon (HxCx) gases. Spectrally optimized cooled detector of 640 x 512 pixels improves the minimum detectable leak rate (MDLR better than 0.35 g/h of CH4).

MILEVA 33 is compatible with RedLook App and RedLook Lite increasing the functionality and simplicity of the device.

SENSIA Sniffer and Mileva 33 merge both methods Smart LDAR and Method 21 in a smart and digital way.

EPA NSPS OOOOa Methane rule compliance

OGI for hydrocarbons gas leaks

Request info

MILEVA 33 is the latest model of Optical Gas Imaging for micro-leaks detection of hydrocarbon (HxCx) gases. Spectrally optimized cooled detector of 640 x 512 pixels improves the minimum detectable leak rate (MDLR better than 0.35 g/h of CH4).

MILEVA 33 is compatible with RedLook App and RedLook Lite increasing the functionality and simplicity of the device.

SENSIA Sniffer and Mileva 33 merge both methods Smart LDAR and Method 21 in a smart and digital way.

EPA NSPS OOOOa Methane rule compliance

Mileva Specifications2019-03-26T11:26:51+00:00
FPA 640 x 512 pixels
Pixel Pitch 15 microns
NETD <15 mK @ 50 ºC
Optical N: 12ºx9º | M: 18ºx13º | W: 31ºx23º
Accuracy +/- 1 ºC (from -10 to 60ºC)
EPA OOOOa for LDAR Compliance
Data USB 3.0 Type A
Power <10 W, 12 Vin
Battery External, >5 hr duration
Weight 2,7 kg
Size  305 mm x 185 mm x 145 mm
Operating Temp. Range -15 to 40 ºC
Minimum detectable leak rate (CH4) 0,35 g/h*
Certifications EMC (EN 61326:2013)

* ΔT gas-background >5 ºC and orifice diameter 1/4”

Gases detected Mileva 332019-03-05T10:18:39+00:00
Methanol Ethanol
Ethylbenzene Heptane
Methane Pentane
MEK MIBK
Benzene 1-Pentene
Toluene Xylene
Ethane Isoprene
Propane Ethylene
Propylene Butane
Octane Hexane

Mileva for leaktightness verification

The ultra-high sensitivity of its cooled detector makes the MILEVA OGI the best option for the leaktightness verification campaigns using carbon dioxide as a trace gas. It allows to visually scan and detect small leaks in an easier way and faster in comparison with traditional methods.

Additionally, MILEVA OGIs are compatible with the SENSIA’s Gas Sniffer 4.0 which allows to obtain the quantitative measurement of the gas on screen, thus fulfilling the Smart LDAR and Method 21 protocols simultaneously.

Mileva for leaktightness verification

The ultra-high sensitivity of its cooled detector makes the MILEVA OGI the best option for the leaktightness verification campaigns using carbon dioxide as a trace gas. It allows to visually scan and detect small leaks in an easier way and faster in comparison with traditional methods.

Additionally, MILEVA OGIs are compatible with the SENSIA’s Gas Sniffer 4.0 which allows to obtain the quantitative measurement of the gas on screen, thus fulfilling the Smart LDAR and Method 21 protocols simultaneously.

Main Features and Specifications

Download the MILEVA 33 Brochure