SENSIA’s Gas Sniffer 4.0 measures the concentration of gases and automatically sends its measurements via Bluetooth. A user-friendly application, installed on a mobile phone or tablet, provides expanded in-field capabilities; gathering measurements, GPS location, photos and audios to generate reports at the moment. Maximize your Smart LDAR efficiency for Industry 4.0.

Multi-function gas detector

SENSIA’s Gas Sniffer 4.0 measures the concentration of gases and automatically sends its measurements via Bluetooth. A user-friendly application, installed on a mobile phone or tablet, provides expanded in-field capabilities; gathering measurements, GPS location, photos and audios to generate reports at the moment. Maximize your Smart LDAR efficiency for Industry 4.0.

Gas sniffer specifications2019-09-04T09:01:06+00:00

Sensor

Target gases

CH4, C3H8, CO2, C2H6

Measurement range

0 to 1.5, 2.5, 5 and 100% volume

Measurement resolution

100 ppm

Accuracy

0.1% vol. or +/-5% for CH4 sensors
0.05% vol. or +/-5% for CO2 and C3H8 sensors

Temperature Range (°C)

-40 to 60

Sniffer

Temperature range

See sensor’s details

Maximum dimensions

630 mm x 50 mm x 50 mm

Weight

675 g

Connectivity

Bluetooth 4.0

Batteries

3 x Type C commercial batteries

Autonomy

More than 16 h

Certifications

EMC (EN 61326:2013)

ATEX || 3G Ex nA || B Gc

IP 54

Sensor’s details

Target gas Measurement Range (% vol.)
CH4 0 to 1.5
CH4 0 to 2.5
CH4 0 to 5
CH4 0 to 100
C3H8 0 to 1.5
C3H8 0 to 2.5
CO2 0 to 1.5
CH4+C2H6 0 to 2.5
CH4+C2H6 0 to 5
CH4+C2H6 0 to 100
Gas sniffer specifications2019-09-04T09:01:06+00:00

Sensor

Target gases

CH4, C3H8, CO2, C2H6

Measurement range

0 to 1.5, 2.5, 5 and 100% volume

Measurement resolution

100 ppm

Accuracy

0.1% vol. or +/-5% for CH4 sensors
0.05% vol. or +/-5% for CO2 and C3H8 sensors

Temperature Range (°C)

-40 to 60

Sniffer

Temperature range

See sensor’s details

Maximum dimensions

630 mm x 50 mm x 50 mm

Weight

675 g

Connectivity

Bluetooth 4.0

Batteries

3 x Type C commercial batteries

Autonomy

More than 16 h

Certifications

EMC (EN 61326:2013)

ATEX || 3G Ex nA || B Gc

IP 54

Sensor’s details

Target gas Measurement Range (% vol.)
CH4 0 to 1.5
CH4 0 to 2.5
CH4 0 to 5
CH4 0 to 100
C3H8 0 to 1.5
C3H8 0 to 2.5
CO2 0 to 1.5
CH4+C2H6 0 to 2.5
CH4+C2H6 0 to 5
CH4+C2H6 0 to 100

Leak Detection & Repair
RedLook APP fusions Method 21 & Smart LDAR Automatic on-field leak reporting.

Leak Detection & Repair

RedLook APP fusions Method 21 & Smart LDAR Automatic on-field leak reporting.

Sniffer app functionalities
  • Extremely accurate NDIR technology

  • High reproducibility

  • Non-zerozing required

  • IoT solution

  • Emissions factor included for quick carbon footprint reporting

  • Temperature measurement on sensor

  • LEDs bar and acoustic signal to indicate the gas detected

Sniffer app functionalities
  • Extremely accurate NDIR technology

  • High reproducibility

  • Non-zerozing required

  • IoT solution

  • Emissions factor included for quick carbon footprint reporting

  • Temperature measurement on sensor

  • LEDs bar and acoustic signal to indicate the gas detected